Manual Cement Compression & Flexure Testing Machines
Manual Cement Compression & Flexure Testing Machines

    Manual Cement Compression & Flexure Testing Machines

    $0.71

    The UTCM-3722.MLP and UTCM-3742.MLP single and double testing chamber Manual compression and flexure testing machines are designed to perform reliable strength and flexure tests on mortar specimens. The manual machines are especially suitable for on-site applications when electric power supply is not available.

    Being a low cost alternative, UTEST manual testing series combine precision and simplicity with the unique design of the manual power pack which enables even an inexperienced operator to perform excellent compression and flexure tests on-site.


    Standards

    EN 196-1, 459-2, 1015-11, 13454-2; ASTM C109, C348, C349; BS 4550-3.4

    These manual testing machines conform to the standards EN 196-1, 459-2, 1015-11, 13454-2; ASTM C 109, C348, C349 by using suitable accessories. They also meet with the requirements of CE norms with respect to operator health and safety.

    The UTEST manual cement compression and flexure testing machines consist of very rigid two column single or double chamber frame, manual power pack and data acquisition system LPI.

    Compression and flexture jigs, distance pieces, and also removable transparent front-rear safety doors (should be factory installed) should be ordered separately.

     

    Manuel Power Pack

    The UTC-4810 Hand Operated (Manual) Hydraulic Power Pack has been designed to be used with range of UTEST Compression machines and flexural frames to use on site and/or where electricity is not available.

    The pump is equipped with a radial piston pump so that the loading is continuous as long as user turns the wheel installed on the pump. The loading is uniform as on an automatic machine.

     

    LPI Battery Operated Digital Readout Unit

    The LPI Battery Operated Digital Readout Unit (UTC-4920LP) has been designed to use with load cells or pressure transducers on different material test applications.

     

    The unit is operates with DC voltage source of -1.5 to 1.5 volts.

    •  Real time numeric display of load and load rate
    • 1 channel with two different calibration table (by changing the sensor belong to other frame, the unit can be control for second test frame)
    •  Peak hold property
    •  Multi-point calibration
    •  Can operate with 2 x AA batteries
    •  Easy preload zeroing
    •  Serial port for PC or printer
    •  8 keys keyboard

    Technical Specifications

    Model

    UTCM-3722

    UTCM-3742

    Test Type

    Compression

    Flexure

    Compression

    Capacity

    250 kN (56.200 lbf)

    15 kN (3370 lbf)

    250 kN(56.200 lbf)

    Class 1 Measuring Range

    1 % for 250 kN

    1 % for 15 kN

    1 % for 50 kN

    The Roughness Value for Texture of Loading Platens

    ≤3.2 μm

     ≤3.2 μm

    ≤3.2 μm

    Lower Platen Dimensions

    165 mm (6,5”)

    165 mm (6,5”)

    165 mm (6,5”)

    Upper Platen Dimensions

    165 mm (6,5”)

    165 mm (6,5”)

    165 mm (6,5”)

    Maximum Vertical Clearance Between Platens

    237 mm (9,3”)

    237 mm (9,3”)

    237 mm (9,3”)

    Piston Diameter

    Ø160 mm (6,3”)

    Ø160 mm (6,3”)

    Ø160 mm (6,3”)

    Maximum Piston Movement with Limit Switch

    20 mm (1,18”)

    20 mm (1,18”)

    20 mm (1,18”)

    Horizontal Clearance

    300 mm (11,8”)

     274 mm (10,8”)

    266 mm (10,47”)

    Oil Capacity

    13 L

    13 L

    Rapid Approach Rate

    50 mm/min

    2 inc/min

    80 mm/min

    3,15 inc/min

    50 mm/min

    2 inc /min

    Dimensions (WxLxH)

    760x500x1580 mm

    (30”x19,7”x62,2”)

    950x500x1580 mm

    ( 37,4”x19,7”x62,2”)

    Weight

    230 kg (518 lbs)

    320 kg (705 lbs)

    The Maximum horizontal clearance for placing the sample is limited by the border of the platens. Sample must be placed such that its ends will not overlap the ends of platens and it must be centered perfectly.The minimum vertical clearance for the specimen can be adjusted using the distance pieces.